BACK
|
Fluke knows
temperature, with more than two decades of
thermometry experience. Today, we offer the
latest in non-contact IR temperature test tools,
probes, accessories, and application expertise
for a complete range of applications. And Fluke
backs its tools with the industry’s best
warranty and highest rated customer service.
Reach for a rugged
Fluke 60 series IR thermometer for jobs
requiring temperature measurement in
hard-to-reach, hot, rotating, or dangerous
situations Get accurate readings over a broad
range of temperatures -40°C to 760°C (-40 °F to
1400 °F). Plus, the enhanced optics allow you to
measure smaller objects further away. All with a
comfortable and easy to use handheld device.
|
|
|
|
| Fluke 60 Series Handheld Infrared
Thermometers |
 |
These handheld portable tools enable
professionals to monitor the status of electrical motors and electrical
panels, research heating and ventilation problems and diagnose car
malfunctions with ease.
Fluke 61:
- Bright laser beam provides easy targeting
- Display clearly supplies data at a glance
- Shock-absorbing holster increases ruggedness
- 0.2 °C (0. 5 °F) resolution up to 275 °C (525 °F)
- Backlight illuminates the screen in the dark
- Automatic sleep mode after 7 seconds extends battery
life
- Alkaline batteries provide 4000 typical measurements
|
Fluke 65:
- Rugged electronics and case with holster
- Bright laser beam provides easy targeting
- Large dual display LCD display clearly supplies data at
a glance
- 0.1º resolution up to 200º (1º resolution above 200º)
- Quality backlight illuminates the screen in the dark
- MIN/MAX provides the variation in any measurement
- Store and recall any single temperature
- Automatic sleep mode after 15 seconds extends battery
life
- Includes C50 soft carrying case, batteries and
instruction sheet
- Measures up to 500 ºC (932 °F)
|
Fluke 63:
- High-resolution optics
- High accuracy: 1 % and repeatability: 0.5 %
- MAX temperature display
- Laser targeting
- Backlit display
- Expanded measurement range up to 535 °C (999 °F)
|
Fluke 66:
- Laser guided sighting system for easy targeting with 1 %
accuracy
- 12-point data logging
- Advanced optics to measure smaller targets at greater
distances
- Adjustable emissivity for more accurate temperature
measurements
- Selectable MAX, MIN, DIF and AVG functions that display
values instantly with Hi/Lo Alarm
- Expanded measurement range up to 600 ºC (1100 ºF)
|
Fluke 68:
- Laser guided sighting system for easy targeting with 1 %
accuracy
- 12-point data logging
- Advanced optics to measure smaller targets at greater
distances
- Adjustable emissivity for more accurate temperature
measurements
- Selectable MAX, MIN, DIF and AVG functions that display
values instantly with Hi/Lo Alarm
- Expanded measurement range up to 760 ºC (1400 ºF)
|
|
|
Specifications |
| Backlit
display for use in poorly lit areas |
| Fluke 61 |
Yes |
| Fluke 65 |
Yes |
| Fluke 63 |
Yes |
| Fluke 66 |
Yes |
| Fluke 68 |
Yes |
|
| Holds
temperature readings |
| Fluke 61 |
Yes |
| Fluke 65 |
Yes |
| Fluke 63 |
Yes |
| Fluke 66 |
Yes |
| Fluke 68 |
Yes |
|
| Range |
| Fluke 61 |
-18 to 275 ºC
(-0 to 525 ºF) |
| Fluke 65 |
-40 to 500 ºC
(-40 to 932 ºF) |
| Fluke 63 |
-32 to 545 ºC
(-25 to 999 ºF) |
| Fluke 66 |
-32 to 600 ºC
(-25 to 1100 ºF) |
| Fluke 68 |
-32 to 760 ºC
(-25 to 1400 ºF) |
|
| MIN/MAX/AVG |
| Fluke 61 |
N/A |
| Fluke 65 |
MIN/MAX |
| Fluke 63 |
MAX |
| Fluke 66 |
All |
| Fluke 68 |
All |
|
| Datalogging |
| Fluke 61 |
N/A |
| Fluke 65 |
N/A |
| Fluke 63 |
N/A |
| Fluke 66 |
Yes |
| Fluke 68 |
Yes |
|
| Distance to
spot ratio |
| Fluke 61 |
8:1 |
| Fluke 65 |
8:1 |
| Fluke 63 |
12:1 |
| Fluke 66 |
30:1 |
| Fluke 68 |
50:1 |
|
| Hi-Lo Alarm |
| Fluke 61 |
N/A |
| Fluke 65 |
N/A |
| Fluke 63 |
Yes |
| Fluke 66 |
Yes |
| Fluke 68 |
N/A |
|
| Optional RTD
probe (contact temperature measurement) |
| Fluke 61 |
N/A |
| Fluke 65 |
N/A |
| Fluke 63 |
N/A |
| Fluke 66 |
Yes |
| Fluke 68 |
Yes |
|
| Emissivity |
| Fluke 61 |
Fixed at 0.95 |
| Fluke 65 |
Fixed at 0.95 |
| Fluke 63 |
Fixed at 0.95 |
| Fluke 66 |
Digitally
adjustable (from 0.1 to 1.0 by 0.01) |
| Fluke 68 |
Digitally
adjustable (from 0.1 to 1.0 by 0.01) |
|
|
Temperature Range |
| Fluke 61 |
| -18 °C (0 °F)
to -1 °C (30 °F) |
± 3 °C (5 °F) |
| above -1 °C
(30 °F) to 275 °C (525 °F) |
± 2% of reading
or 2 °C (3.5 °F) |
| |
(With the
instrument stable between 23-25 °C) |
|
| Fluke 65 |
| Above 0 ºC
(32 ºF) : |
± 2 ºC (± 4 ºF) |
| Below 0 ºC
(32 ºF) : |
± 5 ºC (± 9 ºF) |
| |
(With
instrument stable at 23ºC ± 3 ºC) |
|
| Fluke 63,
66, 68 |
| -32 to -26 ºC
(-25 to -15 ºF): |
±3 ºC (±5 ºF) |
| -26 to -18 ºC
(-15 to 0 ºF): |
±2.5 ºC (±4 ºF) |
| -18 to 23 ºC
(-0 to 73 ºF): |
±2 ºC (±3 ºF) |
| |
For targets
above 23 ºC (73 ºF): ±1% of reading or
±1 ºC (±2 ºF), whichever is greater |
|
|
|
|
|